Meritus Technology / China project support

3D Laser Scanning & Spatial Analysis

Meritus Technology uses 3D laser scanning and spatial analysis to turn accessible industrial geometry into a usable as-built reference. The work package connects capture coverage, survey control and design comparison to the decision your engineers need to make.

Industrial laser-scanning illustration showing survey capture around fabricated structures
Illustrative laser-scanning and geometry capture concept, not a Meritus project dataset.

From reality capture to an engineering reference

Scan planning starts with the required outputs, not the maximum number of points. We review sightlines, obstructions, reflective surfaces, access and the critical tie-ins. Registration targets and a survey control network connect individual scans into a common coordinate system.

Point-cloud registration, coordinate transformation, scan-to-CAD/as-built modelling and CAD/BIM comparison are software functions, not claims about a proprietary platform. Selected geometry may support reverse engineering, clearance analysis, 2D extraction from 3D scans or digital twin data capture; model detail and coverage are agreed before capture.

Repeat capture may support deformation trend analysis when a stable reference, comparable conditions and an agreed monitoring interval are available. A dense point cloud alone does not establish measurement uncertainty or prove that hidden geometry has been verified.

  • Target-based registration and control checks
  • Design-versus-as-built comparison and geometric tolerance assessment
  • Selected measured models, drawings and tie-in dimensions
  • Coverage, registration and uncertainty notes for downstream users
Survey inputs, datum, capture, comparison and report workflowExplanatory schematic only. No project measurement, tolerance or performance result is represented.12345ILLUSTRATIVE GEOMETRY / NOT MEASURED DATAReference and acceptance criteria agreed per project
Inputs → datum and capture → registration → comparison → report. An explanatory workflow, not a proprietary software interface.

An agreed, traceable workflow

Inputs → survey → analysis → deliverables

  1. Inputs: agree drawings/models, tie-ins, tolerances, coordinate requirements and site restrictions.
  2. Survey: plan scanner stations and control targets; capture accessible surfaces and verify critical dimensions.
  3. Analysis: register scans, check control, transform coordinates and compare selected geometry with the current design.
  4. Deliverables: issue the agreed point cloud, model/drawings and deviation report with limitations and file conventions.
Survey inputs, datum, capture, comparison and report workflowExplanatory schematic only. No project measurement, tolerance or performance result is represented.12345ILLUSTRATIVE GEOMETRY / NOT MEASURED DATAReference and acceptance criteria agreed per project
Illustrative work-package sequence. Method, hold points and reporting are agreed before capture.

Acceptance criteria come from the client’s approved drawings, specifications and agreed survey plan. There is no universal tolerance or automatic acceptance based on the instrument used.

In-house capability, project-specific methods

Meritus Technology has an in-house technical team, equipment and software capability for projects across fabrication yards and suppliers in China. We agree the survey method, access requirements and reporting scope around each project’s integration decisions.

Instrument category and software function do not establish an automatic accuracy level. The survey plan, conditions, reference and checks determine fitness for the intended use.

Explore methods, equipment and software
Industrial laser-scanning illustration showing survey capture around fabricated structures
Illustrative laser-scanning and geometry capture concept, not a Meritus project dataset.

Practical handover

Typical outputs

Select the deliverables your engineering and QA teams can use. Formats, coordinate conventions, revision references and limitations are part of the agreed scope.

  • Registered point cloud with coordinate reference and coverage notes
  • Selected 3D mesh or as-built model where included
  • Scan-to-CAD drawings and verified tie-in dimensions
  • Nominal-versus-actual maps, clearance views and analysis report
  • Export files in agreed formats and units
Coordinate records, annotated views and engineering reviewExplanatory schematic only. No project measurement, tolerance or performance result is represented.ILLUSTRATIVE GEOMETRY / NOT MEASURED DATAReference and acceptance criteria agreed per project
Illustrative coordinate record, annotated comparison and review pack. These are not sample project findings.

Application use cases / not project case studies

Engineering situations and the decisions they support

The following typical situations explain a survey approach. They are not claims that Meritus completed a named project. Each assignment uses the client’s approved drawings, specifications and project-specific acceptance criteria.

As-built capture and reverse engineering of existing assets

Asset and fabrication stage
Existing structures or equipment before a modification, tie-in or replacement design.
Dimensional problem
Incomplete or outdated drawings leave uncertainty about actual geometry, clearances and connection locations.
Survey reference and capture method
Scan or survey accessible geometry against agreed control, register the data and verify critical dimensions before design use.
Analysis against design and tolerance
Compare selected geometry with available drawings; distinguish measured surfaces from inferred model elements and record coverage and uncertainty limitations.
Deliverables
Registered point cloud, selected measured model/drawings, tie-in dimensions and uncertainty/coverage notes.
Engineering decision supported
How to plan modifications against the actual asset, and which inaccessible or critical features need further verification.
Industrial laser-scanning illustration showing survey capture around fabricated structures
Illustrative laser-scanning and geometry capture concept, not a Meritus project dataset.
Discuss as-built inputs for a modification

Refinery vessel and process equipment fabrication/installation

Asset and fabrication stage
Vessels, columns and support interfaces through fabrication, lifting and installation.
Dimensional problem
Vessel shape and support/nozzle positions may shift, affecting alignment and the installation envelope.
Survey reference and capture method
Establish an agreed datum and capture accessible 3D as-built geometry, support points and relevant interfaces under the recorded measurement condition.
Analysis against design and tolerance
Analyse deformation and alignment relative to nominal design or a controlled baseline, using the current installation requirements and project tolerances.
Deliverables
Deformation plots, position/alignment records, annotated 3D views and recommendations for engineering review.
Engineering decision supported
Whether fabrication correction or a change in installation planning needs engineering consideration.
Refinery process-vessel survey illustration
Illustrative process-vessel geometry survey. No measured deformation or project outcome is represented.
Discuss process equipment alignment

FPU/FPSO topside module fabrication and fit-up

Asset and fabrication stage
Separately fabricated topside modules before trial fit, lift or integration at the yard.
Dimensional problem
Structural connections and piping interfaces can be individually complete but fail to align when the modules are brought together.
Survey reference and capture method
Establish a survey control network and shared datum; capture critical interfaces, mating surfaces and support positions with total stations and/or scanning.
Analysis against design and tolerance
Transform as-built geometry to design coordinates; compare connection positions and clearances against current approved drawings and project tolerances.
Deliverables
Interface coordinate tables, annotated deviations, clash/fit-up views and a corrective-action list for engineering disposition.
Engineering decision supported
Whether to adjust a connection or module before integration, or request further engineering review.
Industrial module interface and fit-up illustration
Illustrative module interfaces and fit-up coordination, not a documented project or measured result.
Discuss module interfaces before integration

Before you scope a survey

Buyer questions

Survey datum axes, alignment and interface geometryExplanatory schematic only. No project measurement, tolerance or performance result is represented.ILLUSTRATIVE GEOMETRY / NOT MEASURED DATAReference and acceptance criteria agreed per project
Illustrative scope reminder: agree the reference, required evidence and responsible decision-maker.
When is laser scanning preferable to total-station measurement?

Scanning is useful when extensive surface geometry or congested existing assets must be captured. A total station can complement it for discrete critical interfaces, control points and reference transfer. Method choice follows access and tolerance requirements.

How are as-built point clouds compared with design models?

First agree units, revision, coordinate system and comparison features. After registration and control checks, compare selected surfaces or fitted features against nominal geometry and report deviations using the project’s criteria.

Can scanning recover geometry behind obstructions?

No. Additional scanner positions or other survey methods may improve coverage, but inaccessible or hidden surfaces must be recorded as limitations rather than inferred as verified geometry.

Is best-fit alignment suitable for every comparison?

No. Best-fit alignment may reveal shape differences but can obscure position errors relative to the project datum. Agree datum-based or best-fit analysis according to the question being answered.

Can you produce an as-built model for modifications?

Yes, selected as-built modelling can be scoped around tie-ins, interfaces and design needs. Agree model detail, critical dimension checks, output format and coverage before starting.

Start with the engineering question

Discuss scan coverage and deliverables

Tell us what must connect, what is already fabricated and when your team needs measured evidence. Use our existing contact flow to discuss the survey scope; there is no new survey submission form.

Include in your survey brief

  • Asset type and interfaces that matter
  • Site/yard location and access restrictions
  • Available drawings/models and revisions
  • Critical dimensions and governing tolerances
  • Fabrication or installation stage
  • Schedule, hold points and required outputs

Share confidential files through an agreed project channel, not a public page.