Valve-Gate Sequence ControllersRepresentative catalogue configuration. Supplied design and scope are confirmed with your quotation.
Representative catalogue configurations. Related range images illustrate other product families; the approved drawing and quotation define the supplied assembly.
Controls & spare parts
Valve-Gate Sequence Controllers
Valve-gate timing controls with catalogue touchscreen configurations up to 8 independent channels and selectable 1 / 0.1 / 0.01-second resolution.
Key specifications
Touchscreen channels
Up to 8 independent channels in the described catalogue configuration; subject to quotation.
Timing resolution
Selectable 1 s, 0.1 s and 0.01 s resolution; resolution is not a guarantee of actuation accuracy.
Input options
DC 24 V and switching-signal input options are described.
Dimensions, interfaces and acceptance criteria are confirmed against your project data before quotation.
Product technical information
Technical overview
A sequence controller schedules valve-gate outputs from a machine trigger; it is distinct from a temperature controller. The reviewed touchscreen configuration describes up to 8 independent channels and selectable timing resolutions of 1, 0.1 and 0.01 seconds. Those are catalogue configuration options subject to quotation, not a stated timing-accuracy guarantee.
Engineering selection questions
Match outputs to the actual solenoid or actuator circuit, including load and isolation requirements.
Specify trigger polarity and timing sequence with the molding-machine interface.
Validate the sequence on the part; control resolution alone does not establish filling performance.
Design parameters & interfaces
The touchscreen configuration describes up to 8 independent channels, selectable 1 s / 0.1 s / 0.01 s resolution and DC 24 V or switching-signal inputs.
Confirm A / B output behavior, channel disabling, automatic / manual operation and individual / all-channel manual output against the required timing chart.
A separate LED-display format describes A, B and AB modes; do not transfer the touchscreen's channel specification to it. Trigger polarity, output circuit rating, isolation and connectors are data required for quote.
Technical scope
Touchscreen channels
Up to 8 independent channels in the described catalogue configuration; subject to quotation.
Timing resolution
Selectable 1 s, 0.1 s and 0.01 s resolution; resolution is not a guarantee of actuation accuracy.
Input options
DC 24 V and switching-signal input options are described.
Operating modes
A / B output modes, channel disabling, automatic / manual operation and individual / all-channel manual output are described.
Other controller format
A separate LED-display sequence controller describes A, B and AB modes; do not assume the touchscreen channel specification applies to that format.
Acceptance & inspection plan
Check channel count, selected resolution, disabled-channel behavior and sequence against the approved timing diagram.
Observe actual actuator / pin response as well as controller output. Record trigger conditions, delay settings and the molded-part result under the agreed trial.
Applications & selection context
Timed valve-gate output sequencing from the molding-machine trigger.
Manual channel checks during setup where the actuator circuit and machine safety arrangement permit them; this is not a temperature-control function.
Define the application in your enquiry
Channel count, timing chart and desired manual-operation behavior.
Machine trigger specification, input voltage and signal type.
Output circuit details, solenoid loads, connectors and interlock requirements.
Installation & commissioning review
Review machine trigger and solenoid / actuator wiring with qualified personnel; prove channel assignment before enabling motion.
Verify automatic and manual behavior and agreed interlocks with safe access controls. Timing resolution does not establish actual pin-motion accuracy.
Before production release
Check channel count, selected resolution, disabled-channel behavior and sequence against the approved timing diagram.
Observe actual actuator / pin response as well as controller output. Record trigger conditions, delay settings and the molded-part result under the agreed trial.
These are procurement and commissioning review points, not an operating procedure. Use the approved assembly instructions and the receiving site's safety arrangements for the supplied equipment.
Maintenance & technical support
Retain an approved sequence record and connector / I/O schedule before replacing a controller.
When diagnosing late gates, distinguish trigger issues, output wiring and actuator response from timer settings; isolate motion before servicing.
Documentation & handover
Agree the delivered drawing set, component BOM, mechanical interfaces and electrical / utility schedules within the quotation.
Specify the trial report, dimensional records, operating instructions and replacement-part references needed for your receiving team.
Define commissioning assistance, training, warranty terms and spare-parts scope before placing the order; confirm service arrangements for the destination.
Standards references for technical review
The following references help define drawings, interfaces, safety or inspection requirements where applicable. They are not a statement that these products are certified or that every reference applies to every configuration. Agree the applicable edition, scope and required evidence in the quotation.
IEC 60204-1 — Safety of machinery — electrical equipment of machines
Reference for machine electrical integration: supply connection, protective measures, control circuits and documentation. Establish the equipment boundary and applicable project edition before specifying a controller package.
ISO 1101 — Geometrical product specifications — geometrical tolerancing
Use on agreed tooling and interface drawings to define form, orientation, location and run-out requirements. The drawing must state actual tolerances and datums; this reference does not promise a machining accuracy.
ISO 12100 — Safety of machinery — risk assessment and risk reduction
Framework for assessing hot surfaces, stored pressure, moving valve pins and maintenance access in the integrated equipment. A project risk assessment and responsibilities are required; listing this reference is not a safety approval.
Include with your RFQ
Channel count, timing chart and desired manual-operation behavior.
Machine trigger specification, input voltage and signal type.
Output circuit details, solenoid loads, connectors and interlock requirements.
Have a part, a layout or a spare-parts list? Identify the required supply boundary and send the available technical data.