Hot Runner Temperature ControllersRepresentative catalogue configuration. Supplied design and scope are confirmed with your quotation.
Representative catalogue configurations. Related range images illustrate other product families; the approved drawing and quotation define the supplied assembly.
Controls & spare parts
Hot Runner Temperature Controllers
Hot runner temperature controllers: catalogue touchscreen configurations cover 2–120 zones; plug-in card options require sensor and electrical-interface review.
Key specifications
Touchscreen catalogue range
2–120 temperature-control zones; configuration subject to quotation.
Touchscreen construction
A 10.2-inch touchscreen, plug-in maintenance modules, external cooling and incoming-power monitoring are described.
Plug-in card functions
J, K and E sensor types; PID automatic, manual and standby modes; °C / °F display are described.
Dimensions, interfaces and acceptance criteria are confirmed against your project data before quotation.
Product technical information
Technical overview
The reviewed controls range describes touchscreen temperature-control configurations for 2–120 zones and a separate plug-in card controller. These are catalogue configurations subject to quotation, not a promise that every zone count, load or interface is supplied as one standard model. Confirm the zone schedule and electrical drawings before selection.
Engineering selection questions
Count manifold and nozzle zones separately and specify each heater load.
Verify thermocouple type, polarity, grounding and connector pin assignments.
Agree protection, alarm behavior and required electrical documentation for the destination.
Design parameters & interfaces
Build a zone schedule separating manifold and nozzle circuits, with heater voltage / current, sensor type, lead routing and connector pinout for every zone.
The touchscreen catalogue configuration describes 2–120 zones, a 10.2-inch interface, plug-in maintenance modules, external cooling and incoming-power monitoring.
The separate card controller lists J / K / E sensors, PID automatic, manual and standby modes, °C / °F display and AC 80–380 V. These listings do not establish a touchscreen unit's per-zone rating; output capacity, supply phase / frequency and protection are data required for quote.
Compare within this family
Construction variants are compared here, not presented as interchangeable parts.
Hot Runner Temperature Controllers family comparison
Variant
Construction
Confirm before quotation
Touchscreen temperature controller
Compact modular enclosure with a touchscreen interface.
Confirm zone count, per-zone output, supply and connector pinout.
Plug-in card controller
Card-based temperature control with automatic, manual and standby modes.
Confirm sensor type, heater load and the exact card / chassis combination.
Technical scope
Touchscreen catalogue range
2–120 temperature-control zones; configuration subject to quotation.
Touchscreen construction
A 10.2-inch touchscreen, plug-in maintenance modules, external cooling and incoming-power monitoring are described.
Plug-in card functions
J, K and E sensor types; PID automatic, manual and standby modes; °C / °F display are described.
Card voltage listing
AC 80–380 V is listed for the plug-in card controller; confirm the quoted unit's supply, load ratings and wiring.
Compare within this family
Construction variants are compared here, not presented as interchangeable parts.
Hot Runner Temperature Controllers family comparison
Variant
Construction
Confirm before quotation
Touchscreen temperature controller
Compact modular enclosure with a touchscreen interface.
Confirm zone count, per-zone output, supply and connector pinout.
Plug-in card controller
Card-based temperature control with automatic, manual and standby modes.
Confirm sensor type, heater load and the exact card / chassis combination.
Acceptance & inspection plan
Verify the delivered zone count, sensor configuration, output mapping, display units and documented control modes.
Record zone response with a suitable test method and check agreed alarm / fault functions. Define allowable temperature deviation and test conditions contractually rather than assuming a catalogue accuracy.
Applications & selection context
Independent regulation of manifold and nozzle heating zones in a specified hot runner assembly.
Controller replacement or expansion enquiries requiring an exact match of sensor type, heater load, harness and installed electrical supply.
Define the application in your enquiry
Zone count and heater voltage / current per zone.
Supply voltage, phase, frequency and thermocouple schedule.
Have qualified electrical personnel verify supply, protective earth, output loads and connector wiring against the supplied diagrams with power isolated.
Check thermocouple polarity and zone-to-heater mapping. Commission each zone and agree alarm / fault behavior before connecting the complete molding process.
Before production release
Verify the delivered zone count, sensor configuration, output mapping, display units and documented control modes.
Record zone response with a suitable test method and check agreed alarm / fault functions. Define allowable temperature deviation and test conditions contractually rather than assuming a catalogue accuracy.
These are procurement and commissioning review points, not an operating procedure. Use the approved assembly instructions and the receiving site's safety arrangements for the supplied equipment.
Maintenance & technical support
Keep external cooling paths clear and inspect connectors, cable terminations and sensor circuits with power isolated.
Identify plug-in replacements by exact card / chassis combination and electrical revision; retain configuration backups and wiring schedules.
Documentation & handover
Agree the delivered drawing set, component BOM, mechanical interfaces and electrical / utility schedules within the quotation.
Specify the trial report, dimensional records, operating instructions and replacement-part references needed for your receiving team.
Define commissioning assistance, training, warranty terms and spare-parts scope before placing the order; confirm service arrangements for the destination.
Standards references for technical review
The following references help define drawings, interfaces, safety or inspection requirements where applicable. They are not a statement that these products are certified or that every reference applies to every configuration. Agree the applicable edition, scope and required evidence in the quotation.
IEC 60204-1 — Safety of machinery — electrical equipment of machines
Reference for machine electrical integration: supply connection, protective measures, control circuits and documentation. Establish the equipment boundary and applicable project edition before specifying a controller package.
IEC 60584-1 — Thermocouples — EMF specifications and tolerances
Reference for thermocouple type and tolerance. Specify the sensor type, tolerance class, polarity and wiring for each heating zone; controller compatibility alone does not establish the accuracy of the assembled system.
ISO 1101 — Geometrical product specifications — geometrical tolerancing
Use on agreed tooling and interface drawings to define form, orientation, location and run-out requirements. The drawing must state actual tolerances and datums; this reference does not promise a machining accuracy.
ISO 12100 — Safety of machinery — risk assessment and risk reduction
Framework for assessing hot surfaces, stored pressure, moving valve pins and maintenance access in the integrated equipment. A project risk assessment and responsibilities are required; listing this reference is not a safety approval.
Include with your RFQ
Zone count and heater voltage / current per zone.
Supply voltage, phase, frequency and thermocouple schedule.