Direct-Gate Hot Runner NozzlesRepresentative catalogue configuration. Supplied design and scope are confirmed with your quotation.
Representative catalogue configurations. Related range images illustrate other product families; the approved drawing and quotation define the supplied assembly.
Hot runner nozzles
Direct-Gate Hot Runner Nozzles
Compare direct-gate hot runner nozzles with standard tips, extended tips and gate bushings; confirm resin suitability and gate witness.
Key specifications
Tip construction
Standard direct-gate construction uses a thermally conductive tip.
Extended-tip application
An extended tip is described for recessed or restricted gate positions.
Surface trade-off
A gate-bushing version may leave a circular witness around the gate.
Dimensions, interfaces and acceptance criteria are confirmed against your project data before quotation.
Product technical information
Technical overview
Direct-gate nozzles in the reviewed range use a thermally conductive tip. Standard, extended-tip and gate-bushing constructions address different gate-access requirements. The extended-tip description specifically lists PP, PE and PS and advises caution with other materials; suitability must be confirmed for the exact grade.
Engineering selection questions
Treat tip length, resin suitability and gate detail as a coupled selection.
Do not substitute an extended tip solely to reach a gate without reviewing the thermal conditions.
Agree a visual gate-witness reference before tooling release.
Design parameters & interfaces
Dimension the gate location, nozzle installation length, mounting seat and tip reach together; check heat transfer at the gate on the actual mold detail.
The extended-tip description lists PP, PE and PS; an extended tip is not a general substitute for every resin or installation.
Compare standard tip with gate-bushing construction using witness acceptance and service access. Tip / bushing dimensions, power and sensor requirements are data required for quote.
Compare within this family
Construction variants are compared here, not presented as interchangeable parts.
Direct-Gate Hot Runner Nozzles family comparison
Variant
Construction
Confirm before quotation
Standard direct-gate tip
Thermally conductive tip for direct gating.
Check gate detail, heat transfer and accepted witness on the part.
Extended direct-gate tip
Longer tip for recessed or restricted access.
PP, PE and PS are listed; other resin grades need explicit review.
Direct gate with bushing
Precision gate bushing around the direct-gate tip.
Agree the circular bushing witness and the mating mold detail.
Technical scope
Tip construction
Standard direct-gate construction uses a thermally conductive tip.
Extended-tip application
An extended tip is described for recessed or restricted gate positions.
Surface trade-off
A gate-bushing version may leave a circular witness around the gate.
Compare within this family
Construction variants are compared here, not presented as interchangeable parts.
Direct-Gate Hot Runner Nozzles family comparison
Variant
Construction
Confirm before quotation
Standard direct-gate tip
Thermally conductive tip for direct gating.
Check gate detail, heat transfer and accepted witness on the part.
Extended direct-gate tip
Longer tip for recessed or restricted access.
PP, PE and PS are listed; other resin grades need explicit review.
Direct gate with bushing
Precision gate bushing around the direct-gate tip.
Agree the circular bushing witness and the mating mold detail.
Acceptance & inspection plan
Inspect the gate and any bushing ring mark against the agreed visual reference.
Check trial filling and gate behavior with the actual grade; confirm installed dimensions and electrical connections against the approved nozzle drawing.
Applications & selection context
Direct-gating enquiries where the part can accept the selected tip's gate witness.
Recessed or restricted gate access may justify extended-tip review; a bushing construction introduces a potential circular mark around the gate.
Define the application in your enquiry
Resin grade, gate detail and visible-surface requirements.
Nozzle installation length, mold stack and gate position.
Shot weight, heater and thermocouple requirements, drawing or sample for replacement work.
Installation & commissioning review
Inspect mating gate geometry, concentricity, installation depth and nozzle seating before assembly.
Route heater and sensor leads clear of moving and pinching surfaces; verify zone pairing before controlled heat-up.
Before production release
Inspect the gate and any bushing ring mark against the agreed visual reference.
Check trial filling and gate behavior with the actual grade; confirm installed dimensions and electrical connections against the approved nozzle drawing.
These are procurement and commissioning review points, not an operating procedure. Use the approved assembly instructions and the receiving site's safety arrangements for the supplied equipment.
Maintenance & technical support
Inspect tip condition, gate wear, heater fit and sensor continuity during planned service.
Order replacements by drawing revision and mating geometry, not only by a photograph or nominal nozzle length.
Documentation & handover
Agree the delivered drawing set, component BOM, mechanical interfaces and electrical / utility schedules within the quotation.
Specify the trial report, dimensional records, operating instructions and replacement-part references needed for your receiving team.
Define commissioning assistance, training, warranty terms and spare-parts scope before placing the order; confirm service arrangements for the destination.
Standards references for technical review
The following references help define drawings, interfaces, safety or inspection requirements where applicable. They are not a statement that these products are certified or that every reference applies to every configuration. Agree the applicable edition, scope and required evidence in the quotation.
ISO 1101 — Geometrical product specifications — geometrical tolerancing
Use on agreed tooling and interface drawings to define form, orientation, location and run-out requirements. The drawing must state actual tolerances and datums; this reference does not promise a machining accuracy.
IEC 60584-1 — Thermocouples — EMF specifications and tolerances
Reference for thermocouple type and tolerance. Specify the sensor type, tolerance class, polarity and wiring for each heating zone; controller compatibility alone does not establish the accuracy of the assembled system.
ISO 12100 — Safety of machinery — risk assessment and risk reduction
Framework for assessing hot surfaces, stored pressure, moving valve pins and maintenance access in the integrated equipment. A project risk assessment and responsibilities are required; listing this reference is not a safety approval.
Include with your RFQ
Resin grade, gate detail and visible-surface requirements.
Nozzle installation length, mold stack and gate position.
Shot weight, heater and thermocouple requirements, drawing or sample for replacement work.
Have a part, a layout or a spare-parts list? Identify the required supply boundary and send the available technical data.