Wind Tower Cleaning and Coating Repair With embodyne.ai Robots
November 29, 2026 · 4 min read
Steel wind-turbine towers collect two different problems: contamination on the surface, and damage in the coating. Oil and grease run down from the nacelle, dirt builds up, and in coastal or offshore conditions salt deposits accelerate breakdown. Where the coating is damaged, corrosion starts at scratches, impact marks, flange areas and welds. Cleaning and coating repair are separate tasks with separate tools, preparation and acceptance criteria.
The embodyne.ai range includes one robot for each task: the MP-05 Wind Tower Cleaning Robot and the MP-02 Wind Tower Repair Robot.
MP-05: cleaning
The MP-05 removes dirt and oil stains with a brush system. Its product page lists dual sling plus permanent-magnet adhesion, adaptation to conical towers, tower diameters of 2 to 7 m, a maximum speed of 15 m/min and a maximum working wind speed of 15 m/s. It is a cleaning tool: it does not prepare steel for recoating or apply coating.
Use it where the aim is appearance, inspection access or removal of contamination before a coating survey. Confirm with the coating supplier which cleaning agents, if any, are acceptable on the existing system.
MP-02: local coating repair
The MP-02 carries sanding and painting modules for restoring tower coatings. Its page lists an operating height of 150 m and above, a maximum working wind speed of 13 m/s, painting efficiency of 80–100 m²/h and sanding efficiency of 2–6 m²/h. The difference between those two rates matters: on local repair, preparation usually limits output, not painting.
The product page describes work without shutting down the turbine. Whether that is allowed on a given site is the turbine owner’s decision under its own safety rules.
Survey before choosing the task
- Contamination: oil, grease, dirt and salt. Oil must be removed before any repair, or the new coating will not adhere.
- Corrosion: extent and type, from spot rust at damage points to breakdown across larger areas. Rate it against ISO 4628 where the specification uses it.
- Existing coating: system type, total thickness and adhesion. Pull-off (ISO 4624) or cross-cut (ISO 2409) tests show whether the existing coating can be overcoated.
- Repair area: map and measure the defects so the repair scope is stated in square metres and number of locations.
Preparation and compatible repainting
- Clean and degrease first; then prepare the defect and feather the edges of the sound coating.
- Use a repair system approved by the coating manufacturer as compatible with the original system, typically matching the original primer, intermediate and topcoat chemistry.
- Follow the datasheet for minimum and maximum overcoat intervals and film thickness per coat.
- Specify the corrosivity category the repair must suit, for example ISO 12944 C4, C5 or CX, as in the original specification.
Weather and salt exposure
- Respect each robot’s listed maximum working wind speed, and the site’s own wind limit for work at height if lower.
- Keep steel temperature above the dew point by the margin in the coating datasheet (commonly at least 3 °C, measured under ISO 8502-4), within the relative humidity limit.
- On coastal and offshore towers, test soluble salts on prepared areas (ISO 8502-6 and ISO 8502-9) before painting, and wash if they exceed the specified limit.
Inspection
- Visual check of each prepared area before painting, with the on-board view and photographs.
- Dry film thickness per coat and total, to ISO 19840 or the project specification.
- Adhesion testing on trial repairs where the specification calls for it.
- A repair log listing location, area, preparation, batch numbers, climate readings and DFT.
Plan on accepted repairs per shift
Compare methods by the number of repairs or the area that passes inspection per shift, not by robot speed. Include setup and moves between tower locations, weather stand-down, curing between coats, and rework. A trial on representative defects gives the most reliable planning figure for a given tower population.
embodyne.ai equipment is supplied and coordinated by Meritus Technology; Meritus does not manufacture it. Product figures quoted here are the ranges listed on the product pages, not guaranteed site results. Configuration, accessories and suitability are confirmed for each project.
Related LinkedIn discussion: MP-02 wind-tower corrosion repair overview. For the wider method, see Magnetic Crawlers for Industrial Surface Preparation.
Meritus Technology Shanghai
Email: sales@meritustech.com
Phone / WhatsApp: +86 134 8206 1802
www.meritustech.com
Discuss with our team: sales@meritustech.com · +86 13482061802
Discussion on LinkedIn: View the original post and join the comments